5.2
Wiring
5.2.1
Main body (rear) interface
Note:
Individually isolate unused core wires using vinyl tape to prevent the wires from
touching each other.
Cable assembly connectors are easily broken. Plug or unplug them carefully.
Do not shorten the cables.
5.2.2
Waterproofing of each interface
When mounting this equipment at locations subject to water splash or in high humidity,
waterproof each connector and multi cable as shown below.
Waterproofing of connecting portions
1. Wrap self-vulcanizing tape around an area of approximately 30 mm
from each side
of the junction.
2. Wrap vinyl tape around an area of approximately 50 mm from each side of the
junction.
3. Secure both ends of the tape with zip ties to prevent the tape from unraveling.
Power/signal connector
(FRU-CF-F01)
5-7
Ground wire (local supply)
To: Ship's ground