5.1.5. Leveling the antenna unit
Adjust level with using the bubble level installed under the radome. The bubble must be in the
center between lines. If the bubble is on the line or over the line, it means the angle is over 0.3
degrees.
The level adjustment will be completed after all M16 hex nuts are tightened.
Hex bolt
Radome
M16
Hex nut 3pcs
High hex nut 1pc
Split lock washer 2pcs
Flat washer 5pcs
Flat washer (L) 1pc
Radar stand
High hex nut
Internal
unit’s base
Radar stand
Flat washer (L)
Flat washer
Lifting tool
Flat washer
Split lock washer
Hex nut
Flat washer
Radome
Figure 5.2: M16 bolt
Hex nut
Flat washer
Split lock washer
[mm]
500
500
Fig. 5-1: Under the radar