PRIMERGY BX620 S4 Server Blade User’s Guide
Collecting memory dump to other than the system drive
If the memory dump is set to be collected to the system drive (C:\), change the settings so that the
memory dump can be saved to a drive other than the system drive. For setting procedures, refer to "5.1
Memory Dump/Paging File Setting" (
pg.100). If only the system drive exists, or if there is no free
space in any of the drives, perform one of the following:
• Adding a hard disk unit
• Replacing with a higher-capacity hard disk unit
Reducing the installed memory to collect the memory dump
There must be enough free disk space that matches the size of the installed memory; therefore, reduce
the installed memory to a collectable size. Check the memory dump settings when changing the installed
memory size.
For setting procedures, refer to "5.1 Memory Dump/Paging File Setting" (
Changing the write type of the debugging information
If the memory dump cannot be collected, select a write type of debugging information within the range
of free space of the volume size. If the above does not provide a solution, try increasing the size of the
hard disk or adding an additional hard disk unit. For setting procedures, refer to "5.1 Memory Dump/
Restoring the system
In the event where the system file, system configuration, or environment changes during startup are
corrupted, use the repair information stored on the repair disk created at the installation to restore the
system. For restoration procedures, refer to the following:
• "9.6.1 For Windows Server 2008" (
SNMP service startup fails
If the Simple Network Management Protocol (SNMP) is installed, but has not started, perform the
following procedures to start the service.
1
Click [Start] – [Computer Management].
2
Select [Services] on the [Services and Applications] menu.
3
On the details, select [SNMP Service].
4
Select [Start] on the [Action] menu.
To have the service automatically start each time the OS starts, double-click [SNMP Service] on the
details, and select [Automatic] for the [Startup type] setting of the [SNMP Service Properties] window.
Содержание PRIMERGY BX620 S4
Страница 8: ...8 ...
Страница 14: ...14 ...
Страница 46: ...46 Chapter 2 Checking before OS Installation ...
Страница 98: ...98 Chapter 4 Manual OS Installation ...
Страница 104: ...104 Chapter 5 Operations after OS Installation 5 Click the Advanced tab For Windows Server 2008 For Windows Server 2003 ...
Страница 170: ...170 Chapter 6 High Reliability Tools ...
Страница 272: ...272 Appendix ...