219
PRIMERGY BX620 S4 Server Blade User’s Guide
Boot Retry Counter
• No Retry
• Retry1 time
• Retry2 times
• Retry3 times
(Initial value)
• Retry4 times
• Retry5 times
• Retry6 times
• Retry7 times
Sets the maximum number of retries to boot the
operating system within the range of 0 to 7.
ASR&R Boot Delay
(Minute)
2 (Unchangeable)
Sets the standby time for startup after shutdown due
to trouble (such as overheating) in minutes. The
system restarts after the set standby time.
After Power Failure
• Stay Off
• Last State (Initial value)
• Power On
Sets the server operation when power supply is
restored after power failure or turning on the main
power of the Chassis.
• Stay Off
The power stays turned off.
• Last State
The power state before the power failure is
restored.
• Power On
The power is turned on.
Note:
When a UPS scheduled operation is
performed in an OS such as Windows
Server 2003 and Linux, in which the power
turns off after shutdown, set this item to
[Power On]. If this is not set to [Power On],
the server will not start up automatically at
the specified time.
table: Items on the ASR&R Submenu
Item
Setting
Description
Содержание PRIMERGY BX620 S4