Check point 4. Check output voltage of inverter PCB
Check outdoor unit circuit diagram and the voltage. (Measure at inverter PCB side
connector)
1
2
3
4
5
6
7
BLACK
WHITE
YELLOW
RED
FM
FAN MOTOR
BROWN
NOTE:
For details of wiring diagram, refer to
TECHNICAL DATA AND PARTS LIST on page 02-18.
Read wire
DC voltage
Red—Black
280 V (AC 220 V -10 %) to 373 V (AC 240 V +10 %)
→hite—Black
15±1.5 V
-> If the voltage is not correct, replace inverter PCB.
Check point 5. Replace main PCB
If Check point 1 to 4 do not improve the symptom, change main PCB.
End