6. Defrost operation control
Tn: Outdoor unit heat exchanger temperature
Ta: Outdoor temperature
Tn10: Temperature at 10 minutes after compressor start
Tnb: Temperature before 5 minutes
•
Triggering condition
The defrost operation starts when outdoor unit heat exchanger temperature sensor detects the
temperature lower than the values shown below.
–
1st time defrosting after starting operation
Compressor integrating
operation time
Less than 17 min.
17 to 57 min.
More than 57 min.
Condition
Does not operate
Tn ≤ 15.8°F (-9°C) and
Tn-Ta ≥ 9.0°F (5°C)
Tn ≤ 23.0°F (-5°C)
–
2nd time and after
Compressor integrating
operation time
Less than 35 min.
More than 35 min.
Condition
Does not operate
Tn-Tn10 < -9.0°F (-5°C) (Tn ≤ 14.0 °F [-10 °C])
Tn-Tnb < -3.6°F (-2°C) (Tn ≤ 14.0 °F [-10 °C])
Tn ≤ -13.0 °F (-25 °C) (Ta ≥ -4.0°F [-20°C])
Tn ≤ 19.4 °F (-7 °C) or Tn ≤ -13.0 °F (-25 °C) (Ta <
-4.0°F [-20°C])
–
Integrating defrost (Constant monitoring)
Compressor integrating
operation time
More than 240 min. (For
long continuous
operation)
More than 215 min. (For
long continuous
operation
Less than 10 min.* (For
intermittent operation)
Condition
Tn ≤ 26.6 °F (-3 °C)
Tn ≤ 23.0 °F (-5 °C)
Count of the compressor
off: 40 times
*: If the compressor continuous operation time is less than 10 minutes, the number of the com-
pressor off is counted. If any defrost operated, the compressor off count is cleared.
•
Release condition
The defrost operation is released when either one of the conditions below is satisfied.
Outdoor unit heat exchanger temperature
(after 1 minute or later since compressor start)
53.6 °F (12 °C) or more
Compressor operation time
15 minutes
- (04-21) -
6. Defrost operation control
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Содержание AOUH18LMAS1
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2021 11 01 SR_CH01_AS052EF_01 ...
Страница 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 11 17 SR_CH02_AS052EF_04 ...
Страница 39: ...3 TROUBLESHOOTING 2021 11 17 SR_CH03_AS052EF_01 ...
Страница 42: ......
Страница 135: ...4 CONTROL AND FUNCTIONS 2021 11 17 SR_CH04_AS052EF_01 ...
Страница 138: ......
Страница 173: ...5 FILED WORKING 2021 11 17 SR_CH05_AS052EF_01 ...