7-3. Forced cooling operation
The outdoor unit may not operate depending on the room temperature.
→hen FORCED COOLING OPERATION button is pressed more than 10 seconds, forced cooling
operation starts as shown in the table below.
Operation mode
Auto changeover
Fan mode
AUTO
Timer mode
Continuous (no timer setting available)
Setting temperature
75.2°F (24°C)
Vertical airflow direction louver setting
Standard
Horizontal airflow direction louver setting
According to memory position
S→ING
Off
ECONOM↔
Off
Human sensor
Off
• During the forced cooling operation, it operates regardless of room temperature sensor.
• Operation LED and timer LED blink at the same time during the forced cooling operation.
They blink for 1 second ON and 1 second OFF on both operation LED and timer LED (same as
test operation).
By performing one of the following action, test operation will be canceled:
• Pressing the remote controller START/STOP button
• Pressing FORCED COOLING OPERATION button for 3 seconds
• 60 minutes passed after starting forced cooling operation
NOTE:
→hen HEAT operation is selected on the remote controller during forced cooling operation,
heating test run will begin in about 3 minutes.
7-4. MIN. HEAT operation
MIN. HEAT operation performs as below setting when pressing MIN. HEAT button.
Operation mode
Heating
Setting temperature
50°F (10°C)
Fan mode
AUTO
LED display
Economy
Defrost operation
Operate as normal
7-5. ECONOMY operation
The ECONOM↔ operation starts by pressing ECONOM↔ button on the remote controller.
The ECONOM↔ operation is almost the same operation as below settings.
Mode
Cooling/Dry
Heating
Target temperature
Setting tempe2°F (1°C)
Setting temperature -2°F (1°C)
7-3. Forced cooling operation
- (04-24) -
7. Various control
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
C
O
N
TR
O
L
A
N
D
FU
N
C
TI
O
N
S
Содержание AOUH18LMAS1
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2021 11 01 SR_CH01_AS052EF_01 ...
Страница 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 11 17 SR_CH02_AS052EF_04 ...
Страница 39: ...3 TROUBLESHOOTING 2021 11 17 SR_CH03_AS052EF_01 ...
Страница 42: ......
Страница 135: ...4 CONTROL AND FUNCTIONS 2021 11 17 SR_CH04_AS052EF_01 ...
Страница 138: ......
Страница 173: ...5 FILED WORKING 2021 11 17 SR_CH05_AS052EF_01 ...