Type
Wall mounted
Inverter heat pump
Model name
ASUH18LMAS
ASUH24LMAS
Operation range
Cooling
°F (°C)
64 to 90 (18 to 32)
%RH
80 or less
Heating
°F (°C)
86 (30) or less
Remote controller type
→ireless (→ired, Mobile app*
4
[FGLair
™
] [option])
NOTES:
• Specifications are based on the following conditions:
– Cooling: Indoor temperature of 80°FDB (26.67°CDB) /67°F→B (19.44°C→B), and outdoor temperature of 95°FDB (35°CDB) / 75°F→B (23.9°C→B).
– Heating: Indoor temperature of 70°FDB (21.11°CDB) /59°F→B (15.56°C→B), and outdoor temperature of 47°FDB (8.33°CDB) /43°F→B (6.11°C→B).
– *
1
: Heating (17°F): Indoor temperature of 70°FDB (21.11°CDB) /60°F→B (15.56°C→B), and outdoor temperature of 17°FDB (-8.33°CDB) /15°F→B (-9.44°C→B).
– Pipe length: 25 ft (7.5 m), Height difference: 0 ft (0 m). (Between outdoor unit and indoor unit.)
• Protective function might work when using it outside the operation range.
• *
2
: Maximum current is maximum value when operated within the operation range.
• *
3
: Sound pressure level:
–
Measured values in manufacturer’s anechoic chamber.
–
Because of the surrounding sound environment, the sound levels measured in actual installation conditions might be higher than the specified values here.
• *
4
: Available on Google Play
™
store or on App Store
®
. Optional →LAN adapter is also required. For details, refer to the setting manual.
1-1. Indoor unit
- (01-2) -
1. Specifications
G
EN
ER
A
L
IN
FO
R
MA
TI
O
N
G
EN
ER
A
L
IN
FO
R
MA
TI
O
N
Содержание AOUH18LMAS1
Страница 4: ......
Страница 5: ...1 GENERAL INFORMATION 2021 11 01 SR_CH01_AS052EF_01 ...
Страница 15: ...2 TECHNICAL DATA AND PARTS LIST 2021 11 17 SR_CH02_AS052EF_04 ...
Страница 39: ...3 TROUBLESHOOTING 2021 11 17 SR_CH03_AS052EF_01 ...
Страница 42: ......
Страница 135: ...4 CONTROL AND FUNCTIONS 2021 11 17 SR_CH04_AS052EF_01 ...
Страница 138: ......
Страница 173: ...5 FILED WORKING 2021 11 17 SR_CH05_AS052EF_01 ...