7-4
0040
0056
0069
0088
0115
HND
11
15
18,5
22
30
HHD
7,5
11
15
18,5
22
Rated capacity[kVA]
*2
HND
15
21
26
34
44
HHD
13
18
23
29
34
Rated current [A]
*4
HND
40
56
69
88
115
HHD
33
47
60
76
90
Overload capability
HND
HHD
HND
60,7
80,0
97,0
112
151
HHD
42,7
60,7
80,0
97,0
112
Rated current with DCR [A]
*5
HND
42,2
57,6
71,0
84,4
114
HHD
28,8
42,2
57,6
71,0
84,4
HND
15
20
25
30
40
HHD
10
15
20
25
30
D
C
HND
HHD
5,0
8,0
9,0
9,5
10
If this value is 2 to 3%, use an optional AC reactor (ACR).
*9 HND spec. of the type 0012 and 0020: allowable ambient temperature 40
℃
(+104 °F) or less .
The rated output current at HND s pec. is decreased 1% for every 1
℃
(1.8 °F) when ambient tem perature is +40
℃
(+104 °F) or more.
*5 The value is calculated assuming that the inverter is connected with a power supply with the capacity of 500 kVA
(or 10 tim es the inverter capacity if the inverter capacity exceeds 50 kVA) and %X is 5%.
Be sure to use the DCR when applicable motor capacity is 75kW or above.
*6 Obtained when a DC reactor (DCR) is used.
*8 Voltage unbalance (%) =(Max. voltage (V) - Min. voltage (V))/Three -phase average voltage (V) × 67 (IEC 61800 - 3)
HHD
・・・
5.5
~
55kW: 10kHz, 75kW or above type of capacity: 6kHz
HND
・・・
5.5
~
18.5kW: 10kHz, 22
~
55kW: 6kHz, 75kW or above type of capacity: 4kHz
HHD spec.
・・・
type 0001 to 0020: 8kHz, type 0030 to 0115: 10kHz,
HND spec.
・・・
type
0001 to 0020: 4kHz, type 0030 to 0069: 10kHz, type 0088, 0115: 4kHz
The rated output current at HD/ND spec. is decreased 2% for every 1°C (1.8°F) when am bient temperature is +40
℃
(+104 °F) or more.
*1 Fuji 4-pole s tandard motor. At the selection of the inverter rating, consider not only the rating capacity(kW) is enough but also
inverter output current is larger than selected the motor's nominal current.
*2 Rated capacity is calculated by assuming the output rated voltage as 220 V.
*3 Output voltage cannot exceed the power supply voltage.
*4 When the carrier frequency (F26) is set to below value or higher, it is necessary to derate the inverter nominal current.
Specifications
Voltage supply range
150 to 375 V
Mass [kg]
Option
Option
DC reactor(DCR)
Nominal applied motor [kW]
*1
O
u
tp
u
t
ra
ti
n
g
s
Rated voltage[V]
*3
Three-phase 200 to 240V (With AVR)
120% of nominal current for 1min
Voltage: +10 to -15% (Voltage unbalance:2% or less
*8
,
Frequency: +5 to -5%)
150% of nominal current for 1min or 200% of nominal current for 0.5s
Type (FRN____E2S-2_)
Items
Cooling method
Fan cooling
A
C
i
n
p
u
t
ra
ti
n
g
s
Main power supply
Three-phas e 200 to 240V
,
50/60Hz
Voltage/frequency variations
Required power supply capacity
*6
[kVA]
Rated current without DCR [A]
*5
Enclosure (IEC60529)
IP20, UL open type