Chapter 5 FUNCTION CODES
This chapter describes the function codes used to set FRENIC-Ace for Solar Pumping application.
5.1
Function Codes Table
The table below describes the function codes used to set up FRENIC Ace inverter for Solar Pumping application.
For other function codes not described in this manual refer to FRENIC Ace User
’s Manual. In case of using PMS
motor please refer to the FRENIC Ace User
’s Manual for the correct setting of motor parameters.
Code
Keypad code
Name
Data setting range
Factory
default
Setting
F02
F02
Operation method
0: Keypad operation (rotation direction input:
terminal block)
1: External signal (digital input)
2: Keypad operation (forward rotation)
3: Keypad operation (Reverse rotation)
2
1
F03
F03
Maximum output frequency 1
25.0 to 500.0 Hz
200V class
AJKU:60.0
400V class
ACE:50.0
JKU:60.0
App.
(Note 1)
F04
F04
Base frequency 1
25.0 to 500.0Hz
200V class
J:50.0
AUK:60.0
400V class
ACEJ:50.0
UK:60.0
App.
(Note 1)
F05
F05
Rated voltage at base frequency 1
0: AVR disable (output voltage proportional to
power voltage)
80 to 240 V: AVR operation (200V class)
160 to 500V: AVR operation (400V class)
App.
(Note 1)
F06
F06
Maximum output voltage 1
80 to 240V: AVR operation ( 200V class)
160 to 500V: AVR operation ( 400V class)
App.
(Note 1)
F07
F07
Acceleration time1
6.00
F08
F08
Deceleration time1
0.50
F09
F09
Torque boost 1
0.0 to 20.0% (% value against base frequency
voltage 1)
(Note 7)
App.
(Note 1)
F10
F10
Electronic thermal overload
protection for motor 1 (Select motor
characteristics)
1: Enable (For a general-purpose motor with self-
cooling fan)
2: Enable (For an inverter-driven motor (FV) with
separately powered cooling fan)
1
App.
(Note 1)
F11
F11
Electronic thermal overload
protection for motor 1 (Overload
detection level)
0.00 (disable), current value of 1 to 135% of
inverter rated current
(Inverter rated current dependent on F80)
(Note 3)
App.
(Note 1)
F12
F12
Electronic thermal overload
protection for motor 1 (Thermal time
constant)
0.5 to 75.0 min
(Note 4)
App.
(Note 1)
F37
F37
Load selection/
Auto torque boost/
Auto energy-saving operation 1
0: Variable torque load
1: Constant torque load
2: Auto torque boost
3: Auto energy-saving operation (variable torque
load)
4: Auto energy-saving operation (constant
torque load)
5: Auto energy-saving operation with auto torque
boost
1
App.
(Note 1)
F42
F42
Drive control selection 1
0: V/f control without slip compensation
1: Vector control without speed sensor (dynamic
torque vector)
2: V/f control with slip compensation
3: V/f control with speed sensor
4: V/f control with speed sensor and auto torque
boost
6: Vector control for induction motor with speed
sensor
15: Vector control for synchronous motor without
speed sensor nor pole position sensor
0
(Note 5)
200V class
J:200
AK:220
U:230
400V class
EJ:400
A:415
CK:380
U:460
0.00 to 6000 s
6.00 or
20.0