5-18
P01
Motor 1 (No. of poles)
P01 specifies the number of poles of the motor. Enter the value given on the nameplate of the motor. This setting is
used to display the motor speed on the LED monitor and to control the speed (refer to E43). The following
expression is used for the conversion.
Motor rotational speed (min
-1
) = 120/No.of poles x Frequency (Hz)
• Data setting range: 2 to 22 (poles)
P02
Motor 1 (Rated capacity)
P02 specifies the rated capacity of the motor. Enter the rated value given on the nameplate of the motor.
P02 data
Unit
Function
0.01 to 1000
kW
When P99 (Motor 1 selection) = 0, 4, 20 or 21
HP
When P99 (Motor 1 selection) = 1
When accessing P02 with the keypad, take into account that the P02 data automatically updates data of P03, P06
through P13, P53 and H46.
P03
Motor 1 (Rated current)
P03 specifies the rated current of the motor. Enter the rated value given on the nameplate of the motor.
• Data setting range: 0.00 to 2000 (A)