YES: all/at least half of the screw under rotary
agitator plate
NO: screw beside rotary agitator plate
NOTICE! All, or at least half, of the discharge screw must be positioned beneath the
rotary agitator plate!
NOTICE! If using the FBR with raising plate, the raising plate must be cut out
accordingly.
Distance between articulated arms / spring blades
TGR
FBR
0
m
m
Ø1660mm
Ø900mm
0
m
m
Distance between top edge of trough of discharge screw and bottom edge of
articulated arms:
▪ min. 50 mm / max. 90 mm (1)
Distance between top edge of trough of discharge screw and bottom edge of spring
blades:
▪ min. 30 mm / max. 50 mm (2)
NOTICE! Intermediate plate and top edge of trough of discharge screw should be on
the same level (3)
NOTICE! The rotary agitator duct and top edge of trough of discharge screw must be
parallel to the effective area of the rotary agitator!
TGR
FBR
Installation
4
Installation site
Installation and Operating Instructions | M1730116_en