NOTICE
Filling the store when the discharge system is switched off
Equipment damage hazard.
Due to the high resistance from the weight of the fuel on the rotary agitator arms,
the system cannot be started. The drive would be overloaded
❒ Take the following precautions:
➥ The discharge system must be switched on during filling
⇨ See "Filling the store with fuel" [page 36]
NOTICE
If the rotary agitator arms touch the silo wall:
Damage to equipment may occur
If the structural layout means that the rotary agitator arms come into contact with
the silo wall:
❒ The rotary agitator arms can dislodge pieces of plaster
❒ Pieces of wall or plaster that have broken off can block the discharge system
or disrupt the material feed into the boiler, causing a system failure.
➥ If this happens:
❒ Fit an approx. 300 mm high covering made of sheet metal or hardwood to the
silo wall.
➥ Froling offers a ready-made wall protection pack for this purpose.
The staff at Froling will be happy to advise you.
Safety
2
Residual risks
Installation and Operating Instructions | M1730116_en