2.2 Permitted uses
Froling’s “FBR-G / TGR-G with separate rotary agitator drive and discharge screw“ is
solely designed for discharging fuels from dedicated stores. Only use fuels specified in
the “Permitted fuels” section.
The unit should only be operated when it is in full working order. It should be operated
in accordance with the instructions, observing safety precautions, and you should
ensure you are aware of the potential hazards. The inspection and cleaning intervals
in the operating instructions should be observed. Ensure that any faults which might
impair safety are rectified immediately.
The manufacturer or supplier is not liable for any damage resulting from non-permitted
uses.
DANGER
If the device is used incorrectly:
Incorrect use of the system can cause severe injury and damage.
When operating the system:
❒ Observe the instructions and information in the manuals
❒ Observe the details on procedures for operation, maintenance and cleaning,
as well as troubleshooting in the respective manuals.
❒ Any work above and beyond this (e.g. servicing) must be carried out by a
heating engineer approved by Fröling Heizkessel- und Behälterbau GesmbH
or by Froling customer services
2.2.1 Permitted fuels
Wood chips
Criterion
Designation as per
Description acc. to
ÖNORM M 7133
ÖNORM M 7133
EN ISO 17225
Water content
W20
M20
air-dried
W30
M30
suitable for storage
W35
M35
limited suitability for
storage
Size
G30
P16S
Fine wood chip
G50
P31S
Medium-sized wood
chip
EU:
Fuel acc. to EN ISO 17225 - Part 4: Wood chips class A1 / P16S-P31S
Additional for
Germany:
Fuel class 4 (§3 of the First Federal Emissions Protection Ordinance
(BimSchV) - applicable version)
Note on standards
Safety
2
Permitted uses
Installation and Operating Instructions | M1730116_en