❒ Fit flange plate with seal to top of gravity shaft
❒ Fit flange bearing to flange plate on top of gravity shaft
❒ Fit counter bearing for torque support to top of gravity shaft
❒ Install geared motor with torque support and spacer tube onto shaft stub
➥ Thread torque support into counter bearing
➥ Ensure groove in shaft stub is aligned with groove in geared motor
❒ Slide key into groove and fit shaft retainer
If the motor cannot be installed as shown above for reasons of space, it is possible to
turn the drive unit:
❒ Fit the counter plate of the torque support to the opposite side
❒ Turn the geared motor and torque support 180° and fit to the shaft and counter
plate as explained above
❒ Remove screws from trough cover as appropriate
❒ Fit bracket of support element to closed trough with screws previously removed
❒ Fit support element to bracket and secure to floor of boiler room
➥ Adjust height as required
➥
⇨ See "Securing the adjustable feet and support elements" [page 32]
Discharge screw
150/200
Optional
Installation
4
Installing the discharge system
Installation and Operating Instructions | M1730116_en
27