4.3.8 Securing the adjustable feet and support elements
❒ Make 2 holes each in the floor to the left and right of the adjustable feet/support
elements
❒ Drill the holes marked
➥ Drill diameter 15 mm
➥ Min. drill depth 105 mm
❒ Insert the heavy load anchors into the bore holes and tighten with a spanner (SW
17 mm)
4.3.9 Setting the tension of the torsion springs
The joints are fitted with torsion springs for setting the spring pre-tension. The table
below shows the basic settings depending on the rotary agitator diameter.
Torsion arm agitator
TGR 3.5 TGR 4.0 TGR 4.5 TGR 5.0 TGR 5.5 TGR 6.0
Rotary agitator diameter [mm]
3500
4000
4500
5000
5500
6000
Segments per arm
2
2
2
3
3
3
Spring pre-tension
Level
Pre-tension joint 1
B
B
B
B
B
B
Pre-tension joint 2
A
A
A
B
B
B
Pre-tension joint 3
A
A
A
4
Installation
Installing the discharge system
32