74
On the remote control unit:
LOCK LED illuminates
Orange: LOCK OTHER was enabled by itself.
Red:
LOCK OTHER was enabled by other unit.
Red:
LOCK ALL was enabled by any unit.
The
LOCK
button is highlighted (background illuminates)
LED and LCD colors of locked current destination buttons are changed to those set under
LockButtonColor
in the [Web-Based Control:
RU Settings
page] (MFR-40/ 18/ 39RU
and 16RUTA)
To check the
LOCK
status, press the current destination button.
The MENU display shows the LOCK status and the ID number of the unit that has issued the
LOCK command.
The
LOCK
button and LOCK LED on the remote control unit flash if any inhibited operation
such as selecting a source channel is performed when
Lock Other
(or
Lock All)
buttons are
enabled and assigned.
LOCK GROUP
The
LOCK OTHER
function also enables Group
LOCK OTHER
, which allows RU crosspoint
switching only within the same group, and locks RU crosspoint switching in other groups. Any
RU in the same group can lock or release the
LOCK OTHER
command.
LOCK ALL
disables
crosspoint switching from all remote control units and can be unlocked only by remote control
units in the same group.
<LOCK GROUP Setting Example>
This example creates the following three groups from five RU units as shown below using the
Unit ID and Group ID numbers.
1.
Open the [Web-Based Control: Lock Destination page]. Add RU [100], RU [101] and
RU [102] to Group A.
2.
Add RU [103] and RU [104] to Group B.
Once an RU is added to a group, the
LOCK OTHER
/
LOCK ALL
button on the RU changes
to a
Group LOCK OTHER
/
LOCK ALL
button.
DST: 8 [DST8 ]
LK-ID: 103[OTHER PANELS]
LOCK OTHER ON
DST: 8 [DST8 ]
LK-ID: 103[ALL PANELS]
LOCK ALL ON
DST: 8 [DST8 ]
LK-OFF [NOT LOCKED ]
LOCK OFF
If LOCK OTHER or LOCK ALL is ON:
RU [102]
RU [103]
RU [100]
RU [101]
RU [104]
RU [105]
Group A [200]
Group B [201]