64
5-12. Multi-Panel Operation
5-12-1. Outline
Multiple remote control units can be connected to build a large control panel system.
IMPORTANT
Up to 5 remote control units can be linked together.
(Ex.) To build a 96 x 96 maximum control system,
Units to use:
MFR-40RU x 4, and MFR-39RU x 1
Configuration
Destination button assignments to: MFR-40RU x 2 and a part of MFR-39RU
Source button assignments to:
MFR-40RU x 2 and a part of MFR-39RU
This system can control 96 x 96 inputs and outputs without using the PAGE function.
Functions that can be integrated
The following operational procedures can be integrated between the connected remote control
units using the interlock function.
- To select destination channels
- To select destination/source channels and levels using
CONTROL
.
- To enable or disable Lock functions (LOCK LOCAL, LOCK OTHER, and LOCK ALL)
Lock functions in the multi-panel operation
All connected remote control units work as one remote control unit, so:
LOCK LOCAL:
All integrated remote control units are locked locally.
LOCK OTHER:
Restricts remote control units other than those in the multi-panel
operation system from changing crosspoints.
All integrated remote control units can unlock the Lock function.
LOCK ALL:
Restricts all units within the multi-panel operation system from
changing crosspoints.
All integrated remote control units can unlock the Lock function.
RESET
CANCEL
MFR-39RU
REMOTE CONTROL UNIT
POWER
BUSY
LOCK
SETUP
POWER
BUSY
SETUP
LOCK
RESET
MFR-40RU
REMOTE CONTROL UNIT
POWER
BUSY
SETUP
LOCK
RESET
MFR-40RU
REMOTE CONTROL UNIT
POWER
BUSY
SETUP
LOCK
RESET
MFR-40RU
REMOTE CONTROL UNIT
POWER
BUSY
SETUP
LOCK
RESET
MFR-40RU
REMOTE CONTROL UNIT
For System & I/O: MFR-39RU
OUTPUT: MFR-40RU x 2
INPUT: MFR-40RU x 2