Ex. 2: To use the Direct mode TAKE button
Step
Description
1
In Direct mode, the Take function is always enabled.
Select a crosspoint by selecting a destination
and source buttons.
The selected buttons blink.
* To switch multiple crosspoints, repeat the procedure.
2
After completing the crosspoint selection, press the blinking
TAKE
button to
switch the crosspoint/s.
In multiple crosspoint switching, the last set of destination and source buttons are
highlighted.
6-2. Simultaneous Crosspoint Switching
The simultaneous crosspoint switching function allows you to
simultaneously switch multiple
crosspoints
by pressing a button. There are two ways to perform this switching. One is the
Salvo
function that switches by recalling the pre-assigned crosspoints. The other is the
Take
function that
selects multiple crosspoints and switches them simultaneously.
SALVO crosspoints can be saved to either the
r
outing switcher main unit (Main Unit Stored Salvo)
or to the remote control unit (Remote Control Stored Salvo).
6-2-1. Main Unit Stored Salvos
This type of salvo allows you to store crosspoint data to be simultaneously switched into the
routing switcher main unit. The stored data can be recalled from any connected remote control
unit.
Storing Salvo Data to Main Unit
Salvo data for Main Unit Stored Salvo can be stored using the Web-Based Control.
► See [Web-Based Control:
Salvo
page]
Executing Salvos
Use a
SALVO
button (SALVO RECALL (MU)) on the remote control unit as shown in the
procedure below.
1.
Assign a
SALVO
button on the remote control unit. Set the salvo for
MU RECALL
, and
select a Salvo number.
► See Sec. 5-4-3-2. “BTN ASSIGN” and 5-5-2. "Changing Button Assignment"
2.
Press the
SALVO
button to execute the salvo. The crosspoints stored to the salvo
number are simultaneously switched.
6-2-2. Remote Control Stored Salvos
This type of salvo assigns crosspoints to be simultaneously switched to a button. Salvos can
be recalled by the
SALVO
button on the remote control unit that assigned that SALVO. Once a
salvo is executed, crosspoints assigned to the salvo are switched according to the current
remote control level setting.
Remote Control Stored Salvo data can also be stored using the Web-Based Control.
► See [Web-Based Control:
Salvo