58
5-8. Setup Menu (MFR-39RU)
The
SETUP
button allows you to use the
Setup Menu
. Follow the procedure below.
1.
Turn and press
CONTROL
to confirm a submenu selection.
2.
Turn and press
CONTROL
to select and confirm a parameter.
Setup Menu Sub-menu List
Menu
Parameter
Description
IP ADDRESS[RU]
-
Sets the IP address for the remote control
unit. The last 8 bits are the unit ID. (See
Sec. 5-8-1.)
SUBNET MASK[RU]
-
Displays the subnet mask setting in the
remote control unit.
PC-LAN[MU]
NET
Displays the network settings (IP address,
subnet mask, gateway)
GUI
REBOOT
Reboots PC-LAN.
RU CONN ID *
-
Sets the ID to recognize connected remote
control units used in link operation. (See
Sec. 5-12-2.)
RU CONNECT *
ON
OFF
Selects whether to connect and link multiple
remote control units.
BRIGHTNESS
1(dark)
~
8 (bright)
Sets the brightness for buttons, LCD and the
menu display.
BTN ASSIGN
-
Assigns functions to buttons. The same
functions as those assignable in the Setting
mode BTN ASSIGN menu are available. (See
Sec. 5-4-3-2)
VER/ALARM
-
Displays version and alarm information.
REBOOT
YES
NO
Select YES and press CONTROL to start
rebooting.
EXIT
-
Allows you to exit the
Setup Menu
. The
display returns to the one before entering the
Setup Menu
. (The
CANCEL
button works the
same way.)
*
Do not turn off the remote control unit until the
BUSY
indicator, which lights orange, goes off
when changing modes. Doing so will disable the change.
5-8-1. IP ADDRESS [RU]
This menu changes the IP address of remote control units. The last 8 bits (the 4th byte) are the
unit ID.
Turn
CONTROL
to select a byte to be changed. The selected byte will be highlighted. After
changing the value, press
CONTROL
. The next byte to be changed will be highlighted.
SETUP>IP ADDRESS[RU]
192.168.001.100<ENT>