background image

1

FOR USE ONLY WITH DECORATIVE TYPE 

UNVENTED ROOM HEATERS.

Do not store or use gasoline or other flammable
vapors or liquids in the vicinity of this or any other
appliance.

WHAT TO DO IF YOU SMELL GAS

• DO NOT light any appliance.
• DO NOT touch any electrical switches.
• DO NOT use any phone in your building.
• Immediately call your gas supplier from a neighbor’s
phone.
Follow your gas suppliers instructions.
• If your gas supplier cannot be reached, call the fire
department.

Installation and service must be performed by a
qualified installer, service agency or the gas supplier.

WARNING: IF THE INFORMATION IN THIS MANUAL
IS NOT FOLLOWED EXACTLY, A FIRE OR
EXPLOSION MAY RESULT CAUSING PROPERTY
DAMAGE, PERSONAL INJURY OR LOSS OF LIFE.

RADIUM

MODEL:  F500080

UNVENTED WALL MOUNTED ROOM HEATER

INSTALLATION INSTRUCTIONS

(Para Instrucciones en español, ver la página 12)

Installer And Consumer Are

To Retain The Appliance

Manual With The Installed

Appliance

WARNING: IMPROPER INSTALLATION, ADJUSTMENT,
ALTERATION, SERVICE OR MAINTENANCE CAN CAUSE
INJURY OR PROPERTY DAMAGE.  REFER TO THIS
MANUAL. FOR ASSISTANCE OR ADDITIONAL
INFORMATION CONSULT A QUALIFIED INSTALLER,
SERVICE AGENCY OR THE GAS SUPPLIER.

WARNING: DO NOT BUILD A WOOD FIRE. DO NOT

BURN WOOD OR OTHER MATERIAL IN THESE

APPLIANCES.

This is an unvented gas-fired heater. It uses air

(oxygen) from the room in which it is installed.

Provisions for adequate combustion and ventilation air

must be provided. Refer to Combustion and Ventilation

Air Section, Page 3.

This appliance may be installed in an aftermarket,

permanently located, manufactured (mobile) home,

where not prohibited by local codes.

The appliance is only for use with the type of gas

indicated on the rating plate. This appliance is not

convertible for use with other gases.

Issue C - 15.06

INSTALLER: 

LEAVE THIS MANUAL WITH THE APPLIANCE.

CONSUMER:

RETAIN THIS MANUAL FOR FUTURE REFERENCE.

Due to high temperatures, the appliance should be

located out of traffic and away from furniture or

draperies. Do not place clothing or other materials on or

near this appliance.

317-S-04-5

Содержание RADIUM F500080

Страница 1: ...ppliance WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE INJURY OR PROPERTY DAMAGE REFER TO THIS MANUAL FOR ASSISTANCE OR ADDITIONAL INFORMATION CONSULT A QUALIFIE...

Страница 2: ...ional as it may not be operating correctly Section Contents Page No 1 0 General Information 2 2 0 Inventory 2 3 0 Appliance Data 2 4 0 Important Safety Information 2 5 0 Codes 3 6 0 Combustion and Ven...

Страница 3: ...ed from The American National Standards Institute Inc 1430 Broadway New York NY 10018 or National Fire Protection Association Inc Batterymarch Park Quincy MA 02269 Seller of unvented propane or natura...

Страница 4: ...s a combustible material or surface Clearance to the sides of the appliance are 4 but curtains drapes and other fabrics are not permitted within a distance of 20 of the appliance sides No such materia...

Страница 5: ...plate The bottom of the heater may be secured onto the lower mounting studs using the wingnuts or the hex nuts provided Mark the positions shown as Radium attachment points on the wall If the applianc...

Страница 6: ...or partially blocked clean out the ports The heater regulator controls the burner pressure which should be checked at the pressure test points located on the control valve itself shown in figure 5 for...

Страница 7: ...it strip off the burner pipes and clean thoroughly 8 Clean the in line restrictor pilot assembly and the burner tube Do not attempt to remove the pilot injector as this can cause damage 9 Re assemble...

Страница 8: ...ons and run at maximum setting for 15 minutes Position gas sample probe directly over a cata lyst via the outlet grille on top of the appliance Record the carbon diox ide CO2 concentration and then th...

Страница 9: ...nder section B above If you do not smell gas go to next step 6 The pilot is located on the left side behind the burner Figure 8 7 Depress control knob in and turn counterclockwise to the SPARK positio...

Страница 10: ...en fire is on high Poor gas flow to fire check pressure with fire on high If pressure is low remove any restriction in pipework or valve Check all isolators are adequately sized and fully open Check m...

Страница 11: ...G FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS HEATER MAY RESULT IN PROPERTY DAMAGE OR PERSONAL INJURY As our policy is...

Страница 12: ...ALACI N AJUSTE MODIFICACI N REVISI N O MANTENIMIENTO INADECUADOS PUEDEN CAUSAR LESIONES O DA OS MATERIALES CONSULTE ESTE MANUAL SI NECESITA AYUDA O INFORMACI N ADICIONAL CONSULTE A UN INSTALADOR CALIF...

Страница 13: ...gina N 1 0 Informaci n general 13 2 0 Inventario 13 3 0 Especificaciones del aparato 13 4 0 Informaci n de seguridad importante 13 5 0 Normativa 14 6 0 Aire de combusti n y ventilaci n 14 7 0 Requisit...

Страница 14: ...Fuel Gas Code ANSI Z223 1 o NFPA54 que pueden obtenerse en The American National Standards Institute Inc 1430 Broadway New York NY 10018 o National Fire Protection Association Inc Batterymarch Park Qu...

Страница 15: ...ier material susceptible de decolorarse derretirse o deformarse al estar expuesto a un calor moderado debe considerarse como material o superficie combustible Debe dejarse un espacio libre de 4 en los...

Страница 16: ...er sometida a pruebas de estanqueidad antes de aplicar protecci n y o empotrar las tuber as y acoplamientos Una vez que haya seleccionado la posici n final de montaje del aparato teniendo en cuenta lo...

Страница 17: ...be comprobarse en los puntos de prueba de presi n ubicados en la v lvula de control en s ilustrado en la Figura 5 para ajustar la presi n del quemador colector y el regulador La v lvula se encue ntra...

Страница 18: ...del quemador desmonte los tubos del quemador y limpie a fondo 8 Limpie el restrictor en l nea el conjunto del piloto y el tubo del quemador No intente retirar el inyector del piloto puesto que podr a...

Страница 19: ...te al fabricante del equipo Encienda la chimenea siguiendo las instrucciones de uso y deje que funcione durante 15 minutos Ponga la sonda del analizador de gas directamente encima de un catalizador a...

Страница 20: ...n deseada Cierre el panel de acceso a la perilla de control Si la perilla no sale desista y llame inmediatamente a su t cnico de mantenimiento o a su compa a de gas Si despu s de varios intentos el p...

Страница 21: ...I DOBLE EL TERMOPAR PARA HACER QUE EL PILOTO SE MANTENGA ENCENDIDO La llama del piloto se reduce cuando Flujo defectuoso de gas al calentador compruebe la presi n con el calentador en Alto el calentad...

Страница 22: ...VERTENCIA EL NO UBICAR LAS PIEZAS EN LOS LUGARES SE ALADOS EN ESTOS DIAGRAMAS O LA UTILIZACI N DE PIEZAS NO HOMOLOGADAS OFICIALMENTE PARA EL USO CON ESTE CALENTADOR PUEDEN CAUSAR DA OS MATERIALES O LE...

Отзывы: