Versiv Cabling Certification Product Family
Users Manual
68
Tests Without a Remote
You can do the length, resistance, and HDTDR tests without a
remote tester. Table 4 describes the effects of a remote on tests.
1
Attach a coaxial adapters to the main tester.
2
Make sure that the home screen shows the correct settings for
the job.
To make sure that other settings are correct, tap the test setup
panel, make sure the correct test is selected on the
CHANGE
TEST
screen, then tap
EDIT
to see more settings. Table 3 on
page 62 describes the settings.
3
Connect the tester as shown in Figure 28.
4
To do an Autotest: Tap
TEST
on the main tester or press
on the main or remote tester. When the
MEASURE
button
shows, tap it to do the length and resistance tests, which do
not require a remote tester.
To do only the length or resistance test: On the home screen
tap
TOOLS
>
Single Tests
, then tap a test.
To do only the HDTDR test: On the home screen tap
TOOLS
>
Diagnostics
, then tap
HDTDR
.
Note
Because the tester cannot complete all tests, and
the reflection at the end of the cable exceeds the
15% limit for the HDTDR test, the result for an
Autotest without a remote is always FAIL.
Содержание Versiv
Страница 38: ...Versiv Cabling Certification Product Family Users Manual 24...
Страница 86: ...Versiv Cabling Certification Product Family Users Manual 72...
Страница 202: ...Versiv Cabling Certification Product Family Users Manual 188...
Страница 214: ...Versiv Cabling Certification Product Family Users Manual 200...
Страница 234: ...Versiv Cabling Certification Product Family Users Manual 220...
Страница 244: ...Versiv Cabling Certification Product Family Users Manual 230...
Страница 256: ...Versiv Cabling Certification Product Family Users Manual 242...
Страница 258: ...Versiv Cabling Certification Product Family Users Manual 244...