57
6. Install the screw to secure the Assembly.
26466
7. Repeat Steps 1-6 to install the second
Casing Assembly near the top of the freezer
to channel the Touchscreen electrical cable
to the back of the unit.
26467
8. Tuck the switch cable behind the edge of
the casing so that it falls down the side of
the freezer, and not down the front.
26468
Connecting the Unit Syrup Line
The syrup lines attached at the lower back of
the cabinet connect the eight bags of syrup to
the Blending Assembly, with the ninth tube
connecting the Sanitizer Tank to the Blending
Assembly.
1. Locate the 9-Tube Lead at the back of the
cabinet. Remove the dust cap and slide the
coupler casing toward the unit to expose the
lead line coupler.
2. Connect the 9-Tube Lead with the 9-Tube
Assembly, with the 9-hole gasket in
between. Align the 9-hole gasket with the
coupler pins of the 9-Tube Lead and place
the gasket against the coupler. Then align
the coupler pins of the two tube assemblies
and connect them.
9-HOLE GASKET
COUPLER PINS
26431
3. Slide the coupler casing over the connection
and screw each coupler nut into each end of
the casing. Tighten the coupler nuts to
secure the connection.
Содержание TS 80BLD
Страница 4: ...3 PAGE INTENTIONALLY LEFT BLANK...
Страница 7: ...6 General System Overview 1 3 7 9 8 6 4 5 26001 12 2 10 11 Figure 1...
Страница 12: ...11 PAGE INTENTIONALLY LEFT BLANK...
Страница 21: ...20 Spare Parts Kit 10 12 13 2 6 5 11 7 16 3 4 1 14 9 15 8 26007 Figure 7...