30
PRIOR TO APPLICATION
1. Operator(s) should familiarize themselves with the area to be seeded and develop a plan
to ensure uniform application.
2. Develop a plan for communication between operator and driver of the carrying or towing
vehicle to signal for start, stop, turn, etc., through the use of the signal horn.
3. Operator takes up position on the platform. From this point, application will be controlled
by the use of the clutch, valve, discharge assembly, and throttle.
DISCHARGE NOZZLE SELECTION
Nozzles are stored in the tool box. This HydroSeeder
®
is equipped with six nozzles – two long distance and
four fan nozzles. The smaller, long-distance nozzle
is generally better suited for seed, fertilizer, and/or
lime application, while the large, long-distance nozzle
is better for wood fiber mulch application. All of the
fan nozzles are generally suited for both types of
application.
Nozzle
Part Number
Distance (A)
Width (B)
Discharge Time
Lg. Long Distance
008465
Up to 200 ft. (61 m)
-
7.5 min.
Sm. Long Distance
011703
Up to 150 ft. (46 m)
-
30 min.
Sm. Narrow Fan
011707
Up to 75 ft. (23 m)
15 ft. (4.6 m)
30 min.
Sm. Wide Fan
011706
Up to 45 ft. (14 m)
25 ft. (7.6 m)
30 min.
Lg. Narrow Fan
011891
Up to 90 ft. (28 m)
23 ft. (7 m)
10.6 min.
Lg. Wide Fan
011890
Up to 50 ft. (15 m)
35 ft. (10.5 m)
10.6 min.
APPLICATION OF SLURRY
I. GENERAL APPLICATION TECHNIQUES
Do not spray toward power lines, transformers or other
high voltage conductors. Failure to comply WILL result in
severe personal injury or death.
The driver of the carrying vehicle should remain alert for
hazards to the operator, such as low power lines, hanging
branches, etc. Driver should never start or stop abruptly. Failure to comply could result in
minor personal injury, or product or property damage.
1. Determine which nozzle would best suit the application needs according to the
DISCHARGE NOZZLE SELECTION table.
2. Application of seed, fertilizer, and lime: Elevate discharge nozzle no less than 10 degrees
above the area to be sprayed, allowing the slurry to gently rain onto the seed bed.
A
B
Figure 8 – Nozzle Spray Dimensions
Содержание HydroSeeder T170 ML
Страница 27: ...21 DISPLAY LIST SINGLE DATA FORMAT DUAL DATA FORMAT MISCELLANEOUS DISPLAYS ...
Страница 46: ...40 12 6 1 5 3 4 3 7 11 9 8 2 9 10 Figure 9 Lubrication and Adjustment Points ...
Страница 50: ...44 8 ft 10 in 269 cm 16 ft 8 in 508 cm 7 ft 9 in 236 cm ...
Страница 52: ...46 NOTES ...
Страница 58: ...T170 ML2016 Rev A WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 52 1 3 4 5 2 6 7 8 2 ...
Страница 64: ...T170 ML2016 Rev A WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 58 1 2 3 4 5 6 7 8 9 10 11 ...