23
STARTING PROCEDURE
See
HYDROSEEDER
®
SAFETY SUMMARY SECTION before operating
the machine. Failure to comply could result in death or serious injury.
Failure to comply could also result in product or property damage.
Before starting, open recirculation valve, close discharge valve, disengage (turn off) pump clutch,
place agitator control in the
NEUTRAL
position and turn the hydraulic switch to the
REGEN
INTERLOCK
(down) position.
1. Turn key clockwise to the
ON
“
” position. This will activate the
control panel and apply power to the engine ECU. Check the
digital display of the control panel for any fault codes.
If there are fault codes, determine and fix the fault problem before
moving on. If a fault condition exists, the engine ECU may prevent
the engine from starting.
2. Turn the key clockwise to the
START
“
” position until the starter
engages and the engine starts.
3. Allow engine to warm up for 3 to 5 minutes before operation.
NOTE:
This engine has a safety system that will shut the engine off if the engine
oil pressure drops below 10 psi (69 kPa) or if the water temperature
reaches 225˚F (107˚C).
4. After engine has warmed up, turn on the hydraulics system by flipping the hydraulics
toggle switch to the
HYDRAULICS ON
position (all the way up). The switch will
automatically center itself, which is the
ON
position.
AREA COVERAGE - MATERIAL CAPACITY
To determine the coverage per load for any HydroSeeder
®
, three questions must be answered
prior to the application. First, is the job to be done a one-step process (which is when the seed,
fertilizer and mulch are applied proportionally per load) or a two-step process (which is when
the seed and fertilizer are applied alone and then covered by mulch as a second operation)?
Second, at what rates (usually in pounds per 1,000 square feet, or pounds per acre) are the
seeding materials to be applied? Finally, what are the loading capacities of the HydroSeeder
®
?
Application rates vary for different geographic locations, but in general, seed is applied at 6 to 10
pounds per 1,000 square feet; fertilizer is applied at a rate of approximately 400 pounds per acre;
and fiber mulch is applied at 1,500–2,000 pounds per acre. (There are 43,560 square feet in an
acre.) Local agronomists, agricultural extension agents, or soil and water conservation officials
should be contacted for more specific information on application rates for a given area.
The following tables show loading versus coverage rates for the FINN T170 HydroSeeder
®
.
Table A shows rates for one-step applications. The coverage area is determined by the fiber
mulch capacity of the HydroSeeder
®
and the rate at which it is applied.
Table B shows the area coverage when seeding only, where little or no mulch is applied. The
coverage area is determined by the granular solids capacity of the HydroSeeder
®
and the rate at
which the solids are applied.
Содержание HydroSeeder T170 ML
Страница 27: ...21 DISPLAY LIST SINGLE DATA FORMAT DUAL DATA FORMAT MISCELLANEOUS DISPLAYS ...
Страница 46: ...40 12 6 1 5 3 4 3 7 11 9 8 2 9 10 Figure 9 Lubrication and Adjustment Points ...
Страница 50: ...44 8 ft 10 in 269 cm 16 ft 8 in 508 cm 7 ft 9 in 236 cm ...
Страница 52: ...46 NOTES ...
Страница 58: ...T170 ML2016 Rev A WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 52 1 3 4 5 2 6 7 8 2 ...
Страница 64: ...T170 ML2016 Rev A WHEN ORDERING PARTS BE SURE TO STATE SERIAL NUMBER OF MACHINE 58 1 2 3 4 5 6 7 8 9 10 11 ...