46
15.2 Change to Different Input Target
Once an input target barcode is scanned (e.g. product code), instrument will assume all following barcode
scanning is for the same input type (i.e. product code) unless a different input target will be scanned.
15.3 More about Customer / Product Code & Description
When a customer / product code barcode is scanned, instrument will first compare with the customer code /
product code database saved in quick PLU #01 ~ #99 (refer to
11.5.1
and
11.6.1
for details) and for customer
/ product description. Then: -
a.
If a corresponding description has been created for the scanned customer / product code, then
instrument will also carry out the corresponding description.
b.
If there is no corresponding description created for the scanned customer / product code, then
instrument will leave the description blank.
16. Commands
The following types of command are available: -
a.
Keyboard commands are used to simulate key entries on keyboard.
b.
Execution commands are used to execute an action.
c.
System parameter & operation entry setting commands are used to send system parameters and
operation entries to this instrument.
d.
System parameter reading commands are used to read system parameters.
e.
Operation entry reading commands are used to read those operation information entered (e.g. date,
time, product and customer codes), current and accumulated operation results.
f.
Operation result reading commands are used to read current and accumulated operation results.
g.
Customized operation settings PLU saving commands are used to create and save customized
operation settings to PLU.
h.
Customized operation settings PLU reading commands are used to read customized operation
settings saved PLU.
i.
Quick PLU saving Commands are used to create and save operation settings to quick PLU.
j.
Quick PLU reading Commands are used to read operation settings saved in PLU.
Commands can be sent to this instrument from computer through any standard communication program. Refer
to
Appendix L
to
U
for details of the above command types.
The UART port which assigned for command communication should be set to CMD in F16. Refer to paragraph
8
for setting details and procedures.