55
Appendix C: - Lab 1 Output Formats
Lab 1 Print Format
16
When Lab 1 is selected, output in default format will be generated with printed data is sent. No header will be generated when line number is set = 00. See below table
for print format and explanations.
Lab 1 Output Format Illustration Table
Date
Time
Seq
Platform
#
Net
Tare
Gross
Total_WT
QTY
@WT
Total_QTY
Ref.
Result
2018/8/19
11:51:31
5
P2
10.00kg 0.00kg
10.00kg
80.00kg
5000
2.00000g
40002
kg
Below
2018/8/19
11:54:09
1
P1
10.00kg 2.64kg
12.64kg
10.00kg
4999
2.00000g
45001
kg
Accept
2018/8/19
11:54:58
8
PA
20.00kg 2.64kg
22.64kg
110.00kg
10000
2.00000g
55001
kg
Below
2018/8/19
12:10:37
10
PA
20.00kg 2.64kg
22.64kg
130.00kg
10000
2.00000g
65001
pcs
Accept
Notes: -
•
Date = Date of Output
•
Time = Time of Output
•
Seq = Accumulate Sequence No.
•
Platform # =
o
P1 = built-in platform, P2 = external platform, PA = P1+P2.
•
Net = Net Result
•
Tare = Tare Weight
•
Gross = Gross Weight
•
Total_WT = Total Accumulated Weight
•
Qty = Quantity
•
Total_QTY = Total Accumulated Quantity
•
@WT = Unit Weight
•
Ref = Check Target
o
kg = weight in kilogram, g= weight in gram , pcs = quantity
o
Result = Check Results: Accept= Ok, Below = Lo, Above = Hi
16
Lab 1 format does not support Customer or Produce Code or Lab 1 output format.
Содержание C-10 Series
Страница 2: ...2 ...
Страница 95: ...Fidelity Measurement Co Ltd www fi measurement com e mail info fi measurement com ...