14.3 Output and Settings for Alibi Memory & Management Report
Complete both 2 procedures below to output management report.
1.
Define report output comport and report content in F33. Refer to
F33
of
Internal Function Table
on paragraph
6
for details. Avoid assigning RS485 for report output unless Machine ID (set in F18)
is = blank.
2.
Define search for search criteria and date range in F34. Refer to
F34
of
Internal Function Table
on
paragraph
6
for details. Multiple search criteria are acceptable based on condition “AND”. For example,
Operator number XXXX and Product Code YYYY. All transactions which fulfil
both
these 2 criteria will
be outputted.
14.4 Totalization
Except date range “All” is selected, instrument will output the totalized data of below result at the end of the
output.
•
Total number of transactions of the date range
•
Total Net Weight
•
Total Gross Weight
•
Total Piece Count
15. Barcode Scanner
To increase working efficiency, this instrument supports serial and Bluetooth barcode scanner which utilizes
Bluetooth 2.0 for communication. Refer to paragraph
8.1
for setting details.
15.1 Using Barcode Scanner to Simulate Operation Key Input
To simulate
[ZERO]
, [
TARE]
and
[PRINT/M+]
key input, simply scan the corresponding barcodes below.
15.2 Inputting Customer & Product Code and Operator Number.
To change scanner input target, scan either one of the below barcodes, then scan a customer, product or
operator number barcode.
Содержание C-10 Series
Страница 2: ...2 ...
Страница 95: ...Fidelity Measurement Co Ltd www fi measurement com e mail info fi measurement com ...