22
F26
Near Zero Value
** 20d or 20d
1
Near Zero value is useful for dynamic weight check applications to bypass unnecessary Lo alarm during uploading and unloading process.
Notes
: -
•
Value entered valid only when Check function is activated.
•
Near zero weight value can be any value between 20d and Lo limit.
•
Any near zero value which less than 20d will be ignored. Instrument will deem 20d as minimum near zero weight value.
•
The Hi Lo comparison remains non-activated when weight reading is less than the near zero value entered here.
F28
Ask for Operator Number
when Power On
Yes
** No
•
Yes: - Instrument will ask for operator number when power on. Enter 4-digit operator number or press
[CE/x10]
to skip operator
number when asked.
•
No: - Instrument will not ask for operation number when instrument power on.
Notes: -
•
If a different operator number (than what is running now) is entered, instrument displays
Clear
.
•
The operator number entered will be carried out on output formats Lab 3 ~ Lab 5.
F29
Read Calibration & Parameter Counts and Pointer Value
•
C (Calibration count): - shows total times of calibration.
•
O (Parameter set count): - shows total times that the important parameters (F80~F88) has been altered.
Press
[Zero]
to quit to F29 or
[Check]
to display the current pointer value. Pointer Value is the system serial number of the next transaction
to be saved to non-resettable memory.
F30
Allow Letters and Symbols for
Customer & Product Code
Manual Entry
** No
Yes
F31
[PF/Set]
Key Assignment
** Set
(Access to Internal Function Setting when in
Operation Status)
P.F.
(Shift between P1 and P2)
Note
: - When F79 is set to
Off
, Mode Key is always =
Set
and this internal function is not accessible.
F32
External Input Assignment
in1
(Input 1)
in2
(Input 2)
in3
(Input 3)
1 of the below 7 input parameters can be assigned to each external input.