In order to set the DIL switch you require the following
specifications:
– the cylinder stroke length (see type plate on cylinder
used)
– the valve type (see type plate on proportional direc-
tional control valve used)
– the maximum mass load on the slide.
If you wish to position with different masses:
Mass load
•
Positioning with a mass up to 30 % less is usually
without problems.
A further reduction of the mass can lead to a dete-
rioration in positioning and necessitate optimization
(see section 5.3).
•
If necessary, place a basic load on the slide to per-
mit the setting of a higher mass. Positioning can then
be made with greater differences in the mass.
•
Always set the DIL switches for the maximum mass
load used.
A modified DIL switch setting does not become effective
until the operating voltage is switched on again. The
Teach process must then be carried out.
Technical appendix
A-4
SPC-10 9902a
Содержание SPC-10 Series
Страница 1: ...Smart Soft Stop SPC 10 Electronic Pneumatic ...
Страница 3: ...Order no 170 363 Title Manual Designation P BE SPC10 GB II SPC 10 9902a ...
Страница 9: ...VIII SPC 10 9902a ...
Страница 10: ...Chapter 1 Summary of system 1 Summary of system SPC 10 9902a 1 1 ...
Страница 18: ...Chapter 2 Fitting 2 Fitting SPC 10 9902a 2 1 ...
Страница 19: ...Contents 2 Fitting 2 1 Fitting the SPC 10 2 3 2 Fitting 2 2 SPC 10 9902a ...
Страница 22: ...Chapter 3 Installation 3 Installation SPC 10 9902a 3 1 ...
Страница 52: ...Chapter 4 Commissioning 4 Commissioning SPC 10 9902a 4 1 ...
Страница 62: ...Chapter 5 Diagnosis and error treatment 5 Diagnosis and error treatment SPC 10 9902a 5 1 ...
Страница 74: ...Appendix A Technical appendix Technical appendix SPC 10 9902a A 1 ...
Страница 109: ...Technical appendix A 36 SPC 10 9902a ...
Страница 115: ...Technical appendix A 42 SPC 10 9902a ...