3.2.1 Pneumatic emergency stop circuit
In order to put the system into a safe state in the event
of a fault, you will require a pneumatic emergency stop
circuit. Select one of the circuits listed below depending
on the construction and operating characteristics of
your system.
•
cylinder pressureless during emergency stop
•
piston clamped during emergency stop
•
piston moves at reduced speed into the left or right-
hand end position during emergency stop.
If the operating voltage supply for the SPC-10 is
switched off, the MPYE-... will move to the mechanical
mid-position.