Using the complete cylinder stroke
Please observe the following when using the cushioning
length:
– The potentiometer must be longer than the cylinder
stroke used. There must be an electrical reserve.
The following maximum stroke lengths are supported:
Max. usable stroke length
Potentiometer length
215 mm
225 mm
290 mm
300 mm
350 mm
360 mm
440 mm
450 mm
490 mm
500 mm
590 mm
600 mm
735 mm
750 mm
985 mm
1000 mm
1230 mm
1250 mm
1475 mm
1500 mm
1720 mm
1750 mm
1965 mm
2000 mm
– Fit the measuring system symmetrical to the centre
of the cylinder.
– The resulting positioning times depend on the actual
stroke lengths used.
3. Installation
SPC-10 9902a
3-19