5
Proportional directional control valve
•
Install the proportional directional control valve sym-
metrically to the centre of the cylinder and arrange
the tubing symmetrically between the valve (MPYE-
5-...) and the cylinder (DGP(L)-...).
Recommendation: tubing length = cylinder length.
The diagram below shows the tubing of a cylinder with
an MPYE-5-... using an SPC-10 without an emergency
stop circuit.
1
2
Proportional directional control valve type MPYE-5-...-...
Service unit with 5
µ
m filter, without lubricator
Fig. 3/2: Pneumatic circuit diagram
Fit the valve in accordance with the operating instruc-
tions supplied with the valve.
3
1
5
2
4
1
2
3. Installation
3-10
SPC-10 9902a