You will require the following components for imple-
menting fast movement with electronically closed-loop
controlled end position cushioning:
Components
•
the SPC-10
•
a proportional directional control valve type
MPYE-5-...
•
a service unit with 5
µ
m filter, without lubricator
•
a potentiometer type MLO-POT-...-TLF
•
a cylinder, if necessary with mechanical guide
•
two fixed stops
•
24 V DC power supply
•
if necessary, components for a pneumatic emer-
gency stop circuit.
1. Summary of system
SPC-10 9902a
1-5