Connecting the proportional directional control
valve
The valve connection provides the power supply for the
valve and the control voltage for positioning the valve
slide.
PLEASE NOTE
Use only the original cable type KMPYE-....
Pin assignment and core colours of cable KMPYE-...
Pin no. on valve plug
1
2
3
4
5
6
7
24 V load voltage of valve (blue)
0 V (brown)
0 V (green)
Vs (positioning signal 0 ... 10 V) (yellow)
Signal GND (grey)
Not connected (pink)
24 V power supply for valve (white)
1
2
2
3
4
1
Fig. 3/13: Valve connection, pin assignment and core colours
Fasten the plugs with the aid of the union nut in order
to prevent unintentional loosening, e.g. due to shock.
1
3
2
4
6
7
5
3. Installation
3-30
SPC-10 9902a
Содержание SPC-10 Series
Страница 1: ...Smart Soft Stop SPC 10 Electronic Pneumatic ...
Страница 3: ...Order no 170 363 Title Manual Designation P BE SPC10 GB II SPC 10 9902a ...
Страница 9: ...VIII SPC 10 9902a ...
Страница 10: ...Chapter 1 Summary of system 1 Summary of system SPC 10 9902a 1 1 ...
Страница 18: ...Chapter 2 Fitting 2 Fitting SPC 10 9902a 2 1 ...
Страница 19: ...Contents 2 Fitting 2 1 Fitting the SPC 10 2 3 2 Fitting 2 2 SPC 10 9902a ...
Страница 22: ...Chapter 3 Installation 3 Installation SPC 10 9902a 3 1 ...
Страница 52: ...Chapter 4 Commissioning 4 Commissioning SPC 10 9902a 4 1 ...
Страница 62: ...Chapter 5 Diagnosis and error treatment 5 Diagnosis and error treatment SPC 10 9902a 5 1 ...
Страница 74: ...Appendix A Technical appendix Technical appendix SPC 10 9902a A 1 ...
Страница 109: ...Technical appendix A 36 SPC 10 9902a ...
Страница 115: ...Technical appendix A 42 SPC 10 9902a ...