B
CANopen
76
Festo – EXCM-30/-40-...-PF-EN – 1603 – English
B
CANopen
B.1
CANopen object overview
Index
Su
bindex
Designation
Type
Attr.
Explanation
1000h
0
Device type
UINT32
ro
Value = 301
1001h
0
Error register
UINT8
ro
Error register
Bit 0: General error
Bit 1: Excess current motor (I²t)
Bit 2: Voltage monitoring error
Bit 3: Overtemperature motor
Bit 4: Communication error
Bit 5: Device-specific
Bit 6: Reserved (fixed at 0)
Bit 7: Manufacturer-specific
1003h
0
Predefined error field
UINT32
rw/ro
1
Standard error field
UINT32
ro
Last saved error.
Error numbers from 16-bit code.
Lower 2 bytes (LSB) = error code
Upper 2 bytes (MSB) = 0
2
UINT32
ro
3
UINT32
ro
4
UINT32
ro
5
UINT32
ro
6
UINT32
ro
7
UINT32
ro
8
UINT32
ro
1008h
0
Manufacturer device
name
String
ro
Type designation of the controller
“CMXH-ST2-C5-7-DIOP”
1009h
0
Manufacturer hard
ware version
String
ro
Hardware version
(Format “Vxx.yy”)
100Ah
0
Manufacturer soft
ware version
String
ro
Firmware version
(Format “Vxx.yy.bb.pp”)
100Ch
0
Guard time
UINT16
rw
Monitoring time
100Dh
0
Life time factor
UINT8
rw
Factor for monitoring time
1014h
0
COB-ID emergency ob
ject
UINT32
rw
COB-ID of the emergency object
Specification: 128 + Node-ID
1015h
0
Inhibit time EMCY
UINT16
rw
Inhibit time for emergency message
Specification: 0