6
Diagnostics
62
Festo – EXCM-30/-40-...-PF-EN – 1603 – English
Error messages can be represented simultaneously via different display components in the form of LED
indicators and the 7-segments display.
Note
In the representation of the 7-segment display, note the following:
– Four characters are displayed in succession; after that, a space follows.
– Malfunction numbers are represented hexadecimally
(
è
6.3.2 Table of error messages).
General error messages
LED display
7-segment display
Malfunction
Priority
Error in the firmware update:
Switch the device off and on again.
1
System error + malfunction number
2
Error motor 1 + malfunction number
Error motor 2 + malfunction number
3
1)
Displayed only 2x, one after the other
Tab. 6.1
General error messages
CANopen-specific error messages
LED display
Malfunction
Priority
No bus cable connected or no parameters configured.
4
Bus OFF
Warning Limit or Node Guarding
Tab. 6.2
CANopen-specific error messages