5
Operation
42
Festo – EXCM-30/-40-...-PF-EN – 1603 – English
5.2.3
Description of the status bytes SCON/SPOS
The status byte SCON provides feedback about the drive statuses.
Status byte 1 (SCON)
Bit
Function
Description
0
Drive
enabled
ENABLED
= 0
= 1
Drive blocked, output stage switched off
Drive enabled
1
Operation
enabled
OPEN
= 0
= 1
Stop active
Operation enabled, positioning possible
2
Warning
WARN
= 0
= 1
No warning
Warning is present
3
Error
FAULT
= 0
= 1
No error
Error is present, error response active
4
Ready for enable
RDYEN
= 0
= 1
Not ready for enable
Ready for enable
5
Drive control by
FCT
FCT
= 0
= 1
FCT not active, device control through control
interface possible
FCT active, device control through control interface
not possible
6
Feedback
Operating mode
OPM
= 0
= 1
Record selection mode (standard)
Direct mode
7
Reserved
= 0
Reserved
Tab. 5.7
Status byte SCON