6
Diagnostics
66
Festo – EXCM-30/-40-...-PF-EN – 1603 – English
Hex
Type of error/diagnostic memory
Error name
Dec
11
17
Software limit positive
Can be parameterised as:
F
/-/-
Diagnostic memory: optional
The position setpoint has reached or exceeded the respective software end position while jogging.
The error is triggered only once and cannot be triggered again until after the drive has returned to the
permissible area. After the error occurs, jogging can no longer take place in a positive direction.
Travel the respective axis of the planar surface gantry in a negative direction by jogging.
– Acknowledgement option: Error can be acknowledged.
Definable error response(s): A,
B
, C, E, F
12
18
Software limit negative
Can be parameterised as:
F
/-/-
Diagnostic memory: optional
The position setpoint has reached or exceeded the respective software end position while jogging.
The error is triggered only once and cannot be triggered again until after the drive has returned to the
permissible area. After the error occurs, jogging can no longer take place in a negative direction.
Travel the respective axis of the planar surface gantry in a positive direction by jogging.
– Acknowledgement option: Error can be acknowledged.
Definable error response(s): A,
B
, C, E, F
17
23
Logic voltage exceeded
Can be parameterised as:
F
/-/-
Diagnostic memory: optional
The logic voltage monitor has detected an overvoltage. Either due to an internal defect or excessively
high logic voltage.
Check logic voltage directly at the device.
If the error is still present after a reset has been made, it means there is an internal defect and the
device has to be replaced.
– Acknowledgement option: Error can be acknowledged.
Definable error response(s): A,
B
18
24
Logic voltage too low
Can be parameterised as:
F
/-/-
Diagnostic memory: optional
The logic voltage monitor has detected an undervoltage. This is either due to an internal defect or an
overload/short circuit caused by connected peripherals.
Separate device from the entire peripheral equipment and check whether the error is still present
after reset. If it is, it means there is an internal defect and the device has to be replaced.
– Acknowledgement option: Cannot be acknowledged, software reset required.
Parameterisable error response(s):
A