6
Diagnostics
Festo – EXCM-30/-40-...-PF-EN – 1603 – English
65
Hex
Type of error/diagnostic memory
Error name
Dec
0B
11
Parameter file invalid
Can be parameterised as:
F
/-/-
Diagnostic memory: always
No valid parameter set stored.
The default parameter set is loaded automatically. Enter a valid parameter set in the device. If the
error is still present, the hardware may be defective.
– Acknowledgement option: Error can only be acknowledged after eliminating the cause.
Parameterisable error response(s):
A
0C
12
Firmware update execution error
Can be parameterised as:
F
/-/-
Diagnostic memory: optional
The firmware update has not been properly executed/completed.
Check the Ethernet connection between the controller and PC and run the firmware update again.
The previous firmware version remains active until successful completion of the firmware update.
If this error is still present, the hardware may be defective.
– Acknowledgement option: Cannot be acknowledged, software reset required.
Parameterisable error response(s):
A
0D
13
Overcurrent
Can be parameterised as:
F
/-/-
Diagnostic memory: always
Short circuit in the motor, lines or brake chopper. Output stage defective.
Incorrect parameterisation of the current regulator.
Check parameterisation of the current regulator. An incorrectly parameterised current regulator
can generate currents up to the short-circuit limit; as a rule this is clearly noticeable through high
frequency whistling.
If the error message occurs immediately when load voltage is applied:
short circuit in the output stage. The device must be replaced immediately.
If the error message does not occur until the drive is enabled:
– Disconnect the motor plug directly at the controller; if the error still occurs:
Replace controller.
– If the error only occurs when the motor cable is connected:
Check motor and cable for short circuits.
– Acknowledgement option: Cannot be acknowledged, software reset required.
Parameterisable error response(s):
A
0E
14
I
2
t malfunction motor
Can be parameterised as:
F
/-/-
Diagnostic memory: always
The I²t limit for the motor is reached. The motor or the drive system may be insufficient for the re
quired task.
Check design of the drive system and mechanical system for sluggishness.
Reduce load/dynamics, longer breaks.
– Acknowledgement option: Error can be acknowledged.
Definable error response(s): B,
C