6
Diagnostics
70
Festo – EXCM-30/-40-...-PF-EN – 1603 – English
Hex
Type of error/diagnostic memory
Error name
Dec
2D
45
I
2
t warning motor
Can be parameterised as: -/
W
/I
Diagnostic memory: optional
The I²t integral is up to 80 % full.
You can parameterise this message as a warning or suppress it completely as information.
– If parameterisation as a warning: The warning disappears when the I²t integral falls below 80 %.
2F
47
Following error
Can be parameterised as:
F
/W/I
Diagnostic memory: optional
The following error has become too large.
Increase error window.
Acceleration, speed, jerk or load too great? Mechanics stiff?
Motor overloaded (current limitation from I²t monitoring active?)
– For parameterisation as an error: The error can be acknowledged.
Parameterisable error response(s): B, C,
E
, F
– If parameterisation as a warning: The warning disappears when the following error is back in the
permissible range.
30
48
External stop
Can be parameterised as:
F
/-/-
Diagnostic memory: always
The switch-off function “External stop” at the interface for switch-off functions [X4] is active and the
current positioning task has been interrupted.
Deactivate the “External stop” function: Apply a v24 V at pin 15 of the interface for
switch-off functions [X4].
– Acknowledgement option: Error can only be acknowledged after eliminating the cause.
Parameterisable error response(s):
B
31
49
CVE connection
Can be parameterised as:
F
/-/-
Diagnostic memory: optional
A connection error has occurred during “Control via Ethernet” (CVE).
Check the connection: plug disconnected, cable lengths observed, shielded cable used, screening
connected?
– Acknowledgement option: Error can only be acknowledged after eliminating the cause.
Definable error response(s):
B
, C, D, E, F, G
32
50
FCT connection
Can be parameterised as:
F
/W/I
Diagnostic memory: optional
Connection to the FCT has been interrupted.
Check the connection and perform a reset if necessary.
– If parameterisation as a warning: The warning disappears when the connection to the FCT has
been established again.
– For parameterisation as an error: The error can only be acknowledged after the cause is eliminated.
Definable error response(s):
B