D Diagnostic
messages
174
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
Diagnostic messages and fault clearance
34h
Safe Torque Off (STO)
Definable as: F/
W
/I
Diagnostic memory: optional
The “Safe Torque Off ” safety function has been requested.
Observe the separate documentation for the STO function.
– If defined as an error: The error can only be reset after the cause is eliminated.
Definable error reaction(s): 0
– For parameterisation as a warning: The warning disappears if the STO is no longer requested.
37h
Standstill monitoring
Definable as: -/
W
/I
Diagnostic memory: optional
The actual position is outside the downtime window. Parameterisation of the window may be too
narrow.
Check parameterisation of the downtime window.
– If defined as a warning: The warning is no longer active when the actual position is within the
standstill window again or a new record has been started.
38h
Parameter file access
Definable as:
F
/-/-
Diagnostic memory: optional
During a parameter file procedure all other reading and writing routines for the parameter file are
blocked.
Wait until the process is complete. The time between 2 parameter file downloads should not be
less than 3 s.
– Acknowledgement option: Error can only be acknowledged after eliminating the cause.
Definable error response(s):
F
, G
39h
Trace warning
Definable as: -/
W
/-
Diagnostic memory: optional
An error has occurred during trace recording.
Start a new trace recording.
– For parameterisation as a warning: The warning disappears if a new trace has been started.
3Ah
Homing timeout
Definable as:
F
/-/-
Diagnostic memory: optional
Error during homing process in controlled operation. The switch has not been found within a certain
time.
Check the switch configuration and the electric connection of the switch(es).
– Resettable: Error can be reset immediately.
Definable error response(s):
B
, C, E, F
3Bh
Homing method invalid
Definable as:
F
/-/-
Diagnostic memory: optional
Homing error. A homing method block has been set, for example, in open-loop operation.
Select permitted reference travel method.
– Resettable: Error can be reset immediately.
Definable error response(s):
E
, F