PNU 1012
Speeds (Velocities)
Subindex 1 … 3
Class: Array
Data type: int32
FW …
Access: rw2
Reading or parameterisation of the speeds [SINC/s] in the reference mode.
Subindex 1
Search speed (Search Velocity)
Speed when searching for the reference point (REF) near the reference switch or stop.
Subindex 2
Travel speed (Drive Velocity)
Speed when moving to the axis zero point (AZ).
Subindex 3
Creep speed (Crawling Velocity)
Creep speed for leaving the reference/limit switch.
Tab. B.129 PNU 1012
PNU 1013
Acceleration/deceleration (Acceleration/Deceleration)
Subindex 1
Class: Var
Data type: int32
FW …
Access: rw2
Reading or parameterisation of the acceleration/deceleration [SINC/s
2
] in reference mode.
Tab. B.130 PNU 1013
PNU 1015
Max. torque (Max. Torque)
Subindex 1
Class: Var
Data type: int16
FW …
Access: rw2
Reading or parameterisation of the max. permitted torque [‰ force basic value, PNU 555] (via cur
rent limiter) in homing.
If the value is reached for a specific time
è
PNU 1017, the stop is detected as reference point and
the drive travels to the axis zero point.
Tab. B.131 PNU 1015
PNU 1016
Speed limit, stop detection (Block Detection Velocity Limit)
Subindex 1
Class: Var
Data type: int32
FW …
Access: rw2
Reading or parameterisation of the speed limit value for stop detection in homing (homing method: stop).
Tab. B.132 PNU 1016