2 IO-Link
12
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
2.2
Parameterisation of IO-Link device
Before connecting the motor controller to the I-Link master, parameterise the controller interface and
device profile:
– with the FCT plug-in CMMO-ST
è
– with the integrated web server
è
Connecting the motor controller to the PC
è
equipment and functional description of the
motor controller, GDCP-CMMO-ST-LK-SY-....
2.2.1
Parameterisation with the FCT plug-in CMMO-ST
1. Create drive configuration
è
Help for the FCT plug-in CMMO-ST
2. On the application data page (Application Data), determine the control interface (Control Interface):
– “IO-Link”
3. Optionally determine on the controller page (Controller):
– Enable with (Enabled by), determination of the required signals for controller enable:
–
“Fieldbus” (Fieldbus) – factory setting
–
“Digital input ‘Enable’ and fieldbus” (Digital Input 'Enable' and Fieldbus)
4. On the fieldbus page (Fieldbus), determine the device profile (Device Profile):
– “FHPP standard”
– “FHPP st FPC”
5. Establish an online connection.
6. Activate device control (Device Control).
7. Download and save (Store) the parameters.
A restart is required after changing and storing the following parameters with the FCT
plug-in to make the settings active:
– control interface (Modbus, IO-Link, I-Port)
– device profile (FHPP standard, FHPP st FPC)
After parameterisation and restart of the motor controller, the IO-Link master can be configured
è
2.2.2
Parameterisation with the integrated web server
1. Call up online connection with the web browser: “http://192.168.178.1/” (factory setting)
2. To parameterise and store, activate device control (Device Control).
3. In the Control Interface tab, determine and save the control interface (Save):
– “IO-Link”
4. In the FHPP Profile tab, determine and save the device profile (Save):
– “FHPP channel”
– “FHPP + FPC channel”
After parameterisation, the IO-Link master can be configured
è