![Festo CMMO-ST-C5-1-LKP Скачать руководство пользователя страница 58](http://html1.mh-extra.com/html/festo/cmmo-st-c5-1-lkp/cmmo-st-c5-1-lkp_original-instructions-manual_2283105058.webp)
6
Control via FHPP
58
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
Overview of parameters and I/Os in record selection
Parameters involved
è
Parameter
PNU
Record number
400
All parameters of the record data
è
401 ... 442
Start (FHPP)
Record number in control byte 3
CPOS.START = rising edge: start
Jogging and referencing have priority.
Acknowledgement (FHPP)
SPOS.MC = 0: Motion Complete
SPOS.ACK = rising edge: acknowledge start
SPOS.MOV = 1: Drive moves
Requirement
Device control through controller/fieldbus
Motor controller in the status “Operation enabled”
Valid record number is present
Tab. 6.6
Parameters and I/Os with record selection
Содержание CMMO-ST-C5-1-LKP
Страница 182: ......