4 Modbus
TCP
28
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
4.3.3
Data objects for Modbus command “Read Device Identification”
Object ID
Object Name
Access
Content
Basic
0x00
VendorName
R
Manufacturer name
0x01
ProductCode
R
Product code
0x02
MajorMinorRevision
R
Firmware version
Regular
0x00
VendorName
R
Manufacturer name
0x01
ProductCode
R
Product code
0x02
MajorMinorRevision
R
Firmware version
0x03
VendorURL
R
Web address
0x04
ProductName
R
Product name
0x06
UserApplicationName
R
Project name
Tab. 4.4
Data objects for Modbus command “Read Device Identification”
4.3.4
Monitoring functions
TCP/IP connection monitoring (node guard, timeout)
The motor controller supports the TCP/IP connection monitoring.
Node guarding is connection monitoring at the application level. The node guard timeout is reset with
each Modbus client message. If the client application no longer reacts or no more new messages are
received within the timeout, the error reaction “Timeout MODBUS TCP/IP” is triggered.
The timeout time for connection monitoring can be entered between 0 and 5000 ms
è
Values between 0 and 100 ms can be entered, but are limited internally to a minimum of 100 ms.
A value of 0 deactivates the timeout.
In case of a timeout, the fault message 47h or 48h is triggered
è
The error response is adjustable from “warning” to “immediate shut-off of the output stage”.