B Reference
paramete
112
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
B.4.7
Process data – FHPP-data
PNU 320
FHPP status information (FHPP State Information)
Subindex 1, 2
Class: Struct
Data type:
uint32/int32
FW …
Access: ro
Reading of the status data (input data).
Subindex 1
FHPP status byte 1 … 4 (FHPP State Byte 1… 4)
Data type: uint32
Status information on byte 1 … 4 (e.g. SCON, SPOS, ...)
Subindex 2
FHPP status byte 5 … 8 (FHPP State Byte 5… 8)
Data type: int32
Status information on byte 5 … 8 (actual value 2)
Tab. B.42
PNU 320
PNU 321
FHPP control information (FHPP Control Information)
Subindex 1, 2
Class: Struct
Data type:
uint32/int32
FW …
Access: ro
Reading of the control data (output data).
Subindex 1
FHPP control byte 1 … 4 (FHPP Control Byte 1… 4)
Data type: uint32
Control information on byte 1 … 4 (e.g. CCON, CPOS, ...)
Subindex 2
FHPP control byte 5 … 8 (FHPP Control Byte 5… 8)
Data type: int32
Control information on byte 5 … 8 (setpoint value 2)
Tab. B.43
PNU 321