6.5.2
Record structure
A positioning task in record select mode is described by a record made up of setpoint values. Every
setpoint value is addressed via its own parameter number (PNU). A record consists of the setpoint
values with the same subindex.
PNU
Name
Description
401
Record control byte 1
Setting for positioning task: absolute/relative
402
Record control byte 2
Record control: settings for record chaining
404
Setpoint value position
Target position setpoint value
406
Speed
Setpoint speed
407
Acceleration
Nominal acceleration
408
Deceleration
Setpoint deceleration
409
Jerk acceleration
Setpoint value of the jerk during acceleration
410
Load
Load that is moved in addition to the basic load
416
Record chaining target
Record number that is jumped to if the step enabling con
dition is active
417
Jerk deceleration
Setpoint value of the jerk during deceleration
418
Torque limitation
Setpoint value of max. force
421
Record control byte 3
Specific behaviour of the record during ongoing position
ing
423
Final speed
Setpoint value of the final speed at the end of the record.
424
Max. deviation
Setpoint value for max. deviation.
425
MC with record sequencing
Signal status “Motion Complete” (MC) with record se
quencing
426
Start delay
Setpoint value for the start delay time
427
Stroke limit
Setpoint value for the path related to the start position
428
Factor torque pilot control
Share of torque pilot control
430
Position comparator, min.
Lower limit of position comparator
431
Position comparator, max.
Upper limit of position comparator
432
Position comparator damping
time
Setpoint value for position comparator damping time
433
Velocity comparator, min.
Velocity comparator lower limit
434
Velocity comparator, max.
Velocity comparator upper limit
435
Velocity comparator damping
time
Setpoint value for velocity comparator damping time
436
Force comparator, min.
Lower limit of force comparator
437
Force comparator, max.
Upper limit of force comparator
438
Force comparator damping
time
Setpoint value for force comparator damping time
439
Time comparator, min.
Lower limit of time comparator
440
Time comparator, max.
Upper limit of time comparator
Содержание CMMO-ST-C5-1-LKP