B Reference
paramete
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
125
PNU 442
Setpoint value force (Setpoint Value Force)
Subindex 1 … 64
Class: Array
Data type: int16
FW …
Access: rw1
Reading or parameterisation of the target force of a force record [‰ of the force basic value, PNU
555]. The sign of the value determines the direction in which the force is to be built up.
Subindex 1 … 64
Record 1 … 64 (Record 1 … 64)
Target force of the record 1 … 64.
Tab. B.76
PNU 442
B.4.10
Project data – general project data
PNU 500
Project zero point (Project Zero Point)
Subindex 1
Class: Var
Data type: int32
FW …
Access: rw1
Reading or parameterisation of the point of reference for position values in the application
è
PNU 404.
Offset of the axis zero point [SINC] to the project zero point.
Tab. B.77
PNU 500
PNU 501
Software end positions (Software Position Limits)
Subindex 1, 2
Class: Array
Data type: int32
FW …
Access: rw2
Reading or parameterisation of the software end positions [SINC].
A setpoint specification (position) outside the software end positions is not permissible and will res
ult in an error. The offset to the axis zero point is entered.
The software end positions are deactivated if both software end positions have the value = 0.
Subindex 1
Lower limit value (Lower Limit)
Lower software end position
Subindex 2
Upper limit value (Upper Limit)
Upper software end position
Tab. B.78
PNU 501
PNU 502
Max. permitted speed (Max. Velocity)
Subindex 1
Class: Var
Data type: int32
FW …
Access: rw2
Reading or parameterisation of the max. permitted speed [SINC/s].
This value limits the speed in all operating modes.
Tab. B.79
PNU 502