B Reference
paramete
144
Festo – GDCP-CMMO-ST-LK-C-HP-EN – 2017-05b – English
PNU 1025
I
2
t-parameter (I
2
t Parameter)
Subindex 1, 2
Class: Array
Data type: uint32
FW …
Access: rw2
Reading or parameterisation of the I²t integral [ms].
Subindex 1
Motor time constant, rising I²t integral
(Motor Time Constant, Rising I²t-Integral)
Motor time constant of the ascending I²t integral of the temperature monitoring of the motor.
Subindex 2
Motor time constant, descending I²t integral
(Motor Time Constant, Falling I²t-Integral)
Motor time constant of the descending I²t integral of the temperature monitoring of the motor.
For protection of the motor, the motor current is automatically limited to the motor nominal current
è
PNU 1035.
Tab. B.137 PNU 1025
PNU 1026
I
2
t limit values (I
2
t Limits)
Subindex 1, 2
Class: Struct
Data type: uint16
FW …
Access: rw2/ro
Reading or parameterisation of the limit/threshold values [‰] of the I²t-monitoring.
Subindex 1
I²t-warning threshold (I²t Warning Level)
Access: rw2
Warning threshold of the I²t monitoring of the motor.
Subindex 2
I²t-error limit (I²t Error Limit)
Access: ro
Error limit value of the I²t monitoring of the motor.
Tab. B.138 PNU 1026
PNU 1027
Current I
2
t value (Actual I
2
t Value)
Subindex 1
Class: Var
Data type: uint16
FW …
Access: ro
Reading of the current fill level [‰] of the I²t monitoring for the motor.
Tab. B.139 PNU 1027
PNU 1029
Quick stop deceleration (Quick Stop Deceleration)
Subindex 1
Class: Var
Data type: int32
FW …
Access: rw2
Reading or parameterisation of the deceleration with Quick Stop [SINC/s
2
].
Tab. B.140 PNU 1029